Case Study

Point Operation Rollback

On 26th September 2025, The Miro PCM located on 854 points recorded and alarmed a critical operation due to a point operation rollback. The rollback occurs following a successful operation and the points machine rolls back enough for the detection circuit to trigger another operation in the same direction.

AsMoSys Event list for Site 854 26th September is shown in Figure 3.

Figure – PCM-E Point operation Event List showing Critical event on 27-09-2025 at 11:58:15

Figure 4 shows the “Good” point operation for the A Side Normal at 08:50:34

Figure – PCM-E Point operation graph at 26-09-2025 08:50

Figure 5 shows the next operation at 11:58 classified as ‘Critical’. The event is classified as Critical due to it having a very short run duration.

Figure – PCM-E Point operation graph at 26-09-2025 11:58

The Miro PCM can also provide a multi-parameter capture graph for each event. This provides a 10 second capture showing data from all inputs during the event including data from both A and B sides.

Figure – PCM-E Point operation multi-parameter capture graph at 26-09-2025 11:58

In addition to the “Critical” classification due to the run duration exceedance The Miro PCM also detects that the operation was I the same direction and flags an additional “Critical” alarm: “A-Normal-I (IA) Multiple operations I the same direction.

Figure – PCM-E Point operation Event List showing Multiple operations in the same direction Critical event on 27-09-2025 at 11:58:15